Meter Size (in.) Flange Rating 150 LB 300 LB 600 LB 900 LB 1500 LB 2500 LB 1/2 2-1/4x1/2 2-1/2x1/2 3x1/2 4-1/4x3/4 4-1/4x3/4 — 3/4 2-1/2x1/2 3x5/8 3-1/2x5/8 4-1/2x3/4 4-1/2x3/4 — 1 2-1/2x1/2 3x5/8 3-1/2x5/8 5x7/8 5x7/8 5-1/4x7/8 1-1/4 2-3/4x1/2 3-1/4x5/8 3-3/4x5/8 5x7/8 5x7/8 5-3/4x1 1-1/2 2-3/4x1/2 3-1/2x3/4 4-1/4x3/4 5-1/2x1 5-1/2x1 6-1/2x1-1/8 2 3-1/4x5/8 3-1/2x5/8 4-1/4x5/8 5-3/4x7/8 5-3/4x7/8 6-3/4x1 2-1/2 3-1/2x5/8 4x3/4 4-3/4x3/4 6-1/4x1 6-1/4x1 7-1/2x1-1/8 3 3-1/2x5/8 4-1/4x3/4 5x3/4 5-3/4x7/8 7x1-1/8 8-1/2x1-1/4 4 3-1/2x5/8 4-1/2x3/4 5-3/4x7/8 6-3/4x1-1/8 7-3/4x1-1/4 9-3/4x1-1/2 5 3-3/4x3/4 4-3/4x3/4 6-1/2x1 7-1/2x1-1/4 9-3/4x1-1/2 11-1/2x1-3/4 6 4x3/4 4-3/4x3/4 6-3/4x1 7-1/2x1-1/8 10-1/4x1-3/8 13-1/2x2 8 4-1/4x3/4 5-1/2x7/8 7-1/2x1-1/8 8-3/4x1-3/8 11-1/2x1-5/8 15x2 10 4-1/2x7/8 6-1/4x1 8-1/2x1-1/4 9-1/4x1-3/8 13-1/4x1-7/8 19x2-1/2 12 4-3/4x7/8 6-3/4x1-1/8 8-3/4x1-1/4 10x1-3/8 14-3/4x2 21x2-3/4 所有仪表都应该安装上游过滤装置,以使仪表免受管道系统中外来物体的损坏。有关推荐过滤尺寸,请参阅巴顿7000系列产品数据表。卡梅伦提供了启动屏幕作为一个可选配件,以防止外国物体的损害。 避免使用聚四氟乙烯?带身体线程。钢绞线可以进入气流并在转子上收集,造成测量误差。 所有仪表应与可能被**速和水锤损坏的气体或液体“段塞”隔离。 电气安装 在选择电气配件和仪表元件的类型和位置时,要考虑工艺操作温度。从涡轮传导和辐射的热量会损坏电线、连接器、外壳和电路板。仪表可以安装在任何平面上,以便拾取线圈。在温度较高的应用场合,避免将拾音器线圈定位在12点钟的位置。 在可能的情况下,尽量减少信号传输电缆的长度。来自涡轮的信号是低压交流正弦波,可以低至30mV峰值到峰值。电线上的电噪音会对读出仪器造成错误的计数。直接安装累加器或前置放大器是可以选择。如果不能做到这一点,应确保信号电缆不靠近电力电缆、其他信号电缆,或在电气噪声可能干扰信号传输的地方布线。 按照常见的布线安装方法,使用高质量的电缆(双绞线,地线屏蔽)。 流量计位置 巴顿涡轮流量计是在水平位置校准的。因此,当仪表在此平面上工作时,校准的较佳相关性就出现了。但是,该仪表在任何位置都能正常工作。 流量计位置 参见图2.1。要获得较佳精度,流量计的位置取决于几个因素。 ?相对于系统,当流量预期为间歇性时,仪表不应安装在管道系统的低点,因为固体颗粒可能沉淀在转子上,或凝结在转子周围。这些固体颗粒会导致转子冻结或损坏。